• Pass-Through Laboratory Autoclave Creates Sterile Transit Path

Laboratory Products

Pass-Through Laboratory Autoclave Creates Sterile Transit Path

Feb 04 2015

With Priorclave pass-through laboratory autoclaves it is possible to maintain the integrity of laboratories and protect the surround environment by creating a sterile path for media and waste as it passes in and out of a sealed laboratory. This robust design incorporates the highest level of safety with interlocks preventing the simultaneous opening of doors at either end of the chamber.

The QCS 150 Pass-Through autoclave is the latest and smallest double-door autoclave to be introduced by Priorclave, it has a 150 litre front loading stainless steel chamber and is configured to accommodate up to 20% more load capacity than other steam sterilisers of the same specified size.

Double-door autoclaves can be generally considered a bespoke design, albeit one that is created by adding a second door to a standard model. This is where the UK design and laboratory autoclave manufacturing centre of Priorclave is a success as it adapts a standard steam steriliser or develops a totally unique autoclave to meet customer requirements.

Each QCS 150 double-door laboratory autoclave is partly bespoke, Priorclave configuring the functionality of its on-board Tactrol®2 controller to suit lab requirements. A typical set-up could be that only one side of the double door steriliser has access to the full control system, the other side of the autoclave equipped with just a screen to show process status so that lab staff are continually aware when a job is complete and it is safe to remove the media or waste. Where there is concern about bio-hazardous material in the autoclave a microbiological filter can be fitted. Unfiltered condensate is returned to the autoclave for sterilisation.

The steam sterilisation process is controlled by the advanced Tactrol® 2 microprocessor which provides simple yet variable settings of process time and temperature, all supported by graphic indication of cycle status. Just set the temperature and time required, select any options needed and press start, operation is fully automatic once the cycle has started. The tough, clear control panel displays continuously process status.

Each installation site is different, it may require for doors to be hinged on the left or right as well as consideration to location of electrical, water and drain services. This is where the in-depth knowledge of the Priorclave sales and service team is a value asset, are always on hand to advise on critical installation issues, ensuring the autoclave build program accommodates local site requirements for a smooth path from delivery to installation and operation.

The overall design and build of the QCS 150 Pass-Through autoclaves take place in its UK manufacturing centre where Priorclave introduces a bulkhead mount at a correct position to facilitate a strong structural fix into a dividing wall between the sterile lab and non-sterile areas. Once installed the double-door Pass-Through Priorclave is the perfect partner working as an interface between sterile and non-sterile areas. 


Digital Edition

ILM 49.5 July

July 2024

Chromatography Articles - Understanding PFAS: Analysis and Implications Mass Spectrometry & Spectroscopy Articles - MS detection of Alzheimer’s blood-based biomarkers LIMS - Essent...

View all digital editions

Events

ADLM 2024

Jul 28 2024 San Diego, CA USA

InaLab 2024

Jul 30 2024 Jakarta, Indonesia

Miconex

Jul 31 2024 Chengdu, China

ACS National Meeting - Fall 2024

Aug 18 2024 Denver, CO, USA

EMC2024

Aug 25 2024 Copenhagen, Denmark

View all events