• Proven System for Qualitative and Quantitative Content Analysis in the Manufacturing Industries

Mass Spectrometry & Spectroscopy

Proven System for Qualitative and Quantitative Content Analysis in the Manufacturing Industries

The NIRS Analyzer Pro is a proven system for qualitative and quantitative content analysis in the manufacturing industries. Designed for the harsh environment of the production floor, it is based on high resolution diode array technology and provides non-destructive analysis of granules, powders, slurries or opaque samples right in the process line. Real-time measurements and simple operation make it the preferred solution for closed-loop automatic control enabling users to consistently run their production closer to target specifications.

The NIRS Analyzer Pro analyser is available with dedicated interfaces based on reflectance or transmittance technology whichever is best suited for each application area. Measurements are done directly on the moving sample in the process stream. A high-intensity dual-lamp light source illuminates the sample directly or through an optical fibre. The light interacts with the sample and the reflected or transmitted light is measured by the diode array sensor. The backup lamp in the dual lamp system secures uptime and analytical accuracy is unchanged even after switching to a new lamp.

The complete wavelength range is measured instantaneously enabling measurements also on fast moving samples with high accuracy. Calibrations are transferable between units ensuring easy expansion to other measurement points. Integration to process regulations systems can be done through the Metrohm OPC interface.

The NIRS Analyzer Pro complies with the following directives: Low Voltage Directive (LVD) (2006/95/EC); RoHS Directive (2002/95/EC); Packaging and packing and waste Directive (94/62/EC); WEEE Directive (2002/96/EC); ATEX Directive, (94/9/EC), Zone 20 (EN 61241-1-2004 – Explosion safety for DUST-Protection by enclosure tD); IECEx, Zone 20 (IEC 61241-1-2004 – Explosion safety for DUST-Protection by enclosure tD); REACH Directive (1907/2006/EC); Developed and produced according to Metrohm ISO approval ISO 9001.


Digital Edition

Lab Asia 31.6 Dec 2024

December 2024

Chromatography Articles - Sustainable chromatography: Embracing software for greener methods Mass Spectrometry & Spectroscopy Articles - Solving industry challenges for phosphorus containi...

View all digital editions

Events

Smart Factory Expo 2025

Jan 22 2025 Tokyo, Japan

Instrumentation Live

Jan 22 2025 Birmingham, UK

SLAS 2025

Jan 25 2025 San Diego, CA, USA

Arab Health

Jan 27 2025 Dubai, UAE

Nano Tech 2025

Jan 29 2025 Tokyo, Japan

View all events