Temperature control and sterilising
Reduce process costs with the NEW Unistat 905w from Huber
May 05 2010
With 6kW heating power, cooling powers from 4,5kW @ 0°C and 0,7kW @ -80°C and a temperature range of -90 to 250°C the new Unistat® 905w brings a tailored cryogenic solution to lower volume reactors.
The Unistat® range was introduced to the market in 1991. With a temperature range from -120 to +425°C, the Unistats® are designed for demanding temperature control applications where reliability, predictability and tight control are a necessity in a constantly changing reaction mass. Critical process temperatures can be maintained through mixing, ingredient addition, exothermic and endothermic reactions. This level of temperature control can lead to increased yields, lower resource consumption and lower running costs, making the Unistats® a more efficient and profitable alternative to other temperature control methods.
Designed to give the highest possible flow rates, the new Unistat® 905w features an efficient variable-speed pump with soft start. This enables the safest and fastest ramp rates resulting in tighter control of process temperature while protecting your reactor and maximising process efficiencies. The pressure of the thermal fluid is closely controlled and monitored by an adaptive controller that brings a new level of precision to thermal control that can be delivered to a wide variety of applications.
A hydraulically sealed circulation thermostat, the Unistat® 905w allows fluids to be used safely above flash points without the fear of ignition and associated greasy residue that comes from oil vapours. In addition, because the fluids are not exposed to the atmosphere whilst being heated and cooled, they do not degrade, dramatically extending their lifetime by years.
Consistent with the entire Unistat® range, the Unistat® 905w features the Unistat® Pilot, an easy to use touch screen controller. With simple to access menus displaying all the key parameters, including, process temperature, jacket temperature, fluid pressure and safety settings users can view dynamic data in a real-time graphic format.
All units are CFC and H-CFC free and have the option for 100% natural refrigerants.
For more information about the new Unistat® 905w or to download the case studies visit: our website or e-mail: info@huber-online.com
Digital Edition
ILM 50.2 March 2025
March 2025
Chromatography Articles - Effects of small deviations in flow rate on GPC/SEC results Mass Spectrometry & Spectroscopy Articles - Waiting for the present to catch up to the future: A bette...
View all digital editions
Events
Mar 31 2025 Beijing, China
Microbiology Society Annual Conference 2025
Mar 31 2025 Liverpool, UK
Apr 01 2025 New York, USA
Apr 02 2025 Saigon, Vietnam
Apr 09 2025 Tokyo, Japan