Temperature control and sterilising
Magnum 91 Powerful Temperature System for Reactors Up to 50 Litres
Jun 23 2008
With the ,Magnum 91‘ JULABO offers a powerful highly dynamic temperature control system for demanding external temperature applications, like e.g. temperature control of reactors up to 50 litres. The advantages are rapid heat-up and cool-down within the working temperature range from –91 to +250°C as well as an immediate control of exothermic and endothermic reactions.
The typical applications include control of jacketed reactor vessels, reactor systems, pilot plants and reaction blocks as well as polymerization, polycondensation, distillation and synthesis chemistry. The water-cooled unit offers a heating capacity of 6 kW as well as a cooling capacity of 5 kW at +20°C, 4 kW at 40°C, 2.5 kW at –60°C and 0.6 kW at –80°C.
The circulation pump is electronically adjustable and reaches a flow rate of 24 to 35 l/min resp. a pressure of 0.8 to 2.2 bar. With the intelligent ICC cascade temperature control rapid results with high precision are reached. The temperature stability is between +/-0.05 and +/-0.2°C. For time and temperature depending processes there is an integrated programmer with 6x60 program steps. Additionally the system has a closed tempering circuit, here the advantages are a reduced oxidation and a longer lifetime of the bath fluid – unpleasant odors and vapors do not get outside. Further features are an RS232/RS485 interface, a connection for external Pt100 sensor, an early warning system for temperature limit values as well as a keypad, which is divided into two, with VFD- and LCD display for user input.
The temperature stability is between +/-0.05 and +/-0.2 deg C. For time and temperature depending processes there is an integrated programmer with 6x60 program steps. Additionally the system has a closed tempering circuit, here the advantages are a reduced oxidation and a longer lifetime of the bath fluid - unpleasant odors and vapors do not get outside. Further features are an RS232/RS485 interface, a connection for external Pt100 sensor, an early warning system for temperature limit values as well as a keypad, which is divided into two, with VFD- and LCD display for user input.
Contact Julabo
Digital Edition
ILM 50.2 March 2025
March 2025
Chromatography Articles - Effects of small deviations in flow rate on GPC/SEC results Mass Spectrometry & Spectroscopy Articles - Waiting for the present to catch up to the future: A bette...
View all digital editions
Events
Mar 31 2025 Beijing, China
Microbiology Society Annual Conference 2025
Mar 31 2025 Liverpool, UK
Apr 01 2025 New York, USA
Apr 02 2025 Saigon, Vietnam
Apr 09 2025 Tokyo, Japan