• New Reaction Monitoring Solutions for benchtop NMR Spectrometer Released

Mass Spectrometry & Spectroscopy

New Reaction Monitoring Solutions for benchtop NMR Spectrometer Released

Jan 13 2016

Magritek have released new solutions that enable straightforward reaction monitoring on the Spinsolve benchtop NMR spectrometer. This is complemented with a series of applications notes illustrating the multiple uses for the Spinsolve benchtop NMR spectrometer.

With high stability and spectral resolution Magritek’s Spinsolve delivers measurements that are quantitative with only minimal calibration. The signal has a linear response to concentration and it is generally not sensitive to the matrix. Results are representative of the complete sample and the measurement is non-destructive.

To enable the Spinsolve spectrometer for reaction monitoring Magritek have created full solutions with either glass flow cells or PTFE flow tubing that fit through the completely clear bore of the instrument. The glass flow cell option offers a large sample volume in the sampling region of the spectrometer and a narrow internal diameter outside of that zone. This gives the maximum signal to noise output with minimal fluid in the flow system. The hardware kit is completed with a peristaltic pump, appropriate tubing, and a stand to provide access below the spectrometer. Complementing the hardware is the full experiment scripting capability and pump control available in the latest instrument software. Stop-flow or continuous flow monitoring is straightforward to set up.

A range of application notes available on the Magritek website help Spinsolve users solve specific problems. For example, consider fermentation processes. This is a naturally occurring chemical event. One application note describes how easy it is to monitor a simple fermentation process - to follow the conversion of fructose and glucose into ethanol and carbon dioxide - and to easily get chemical conversion rates and to see where the optimal end point has occurred. The note shows that a simple flow loop setup allows on-line reaction monitoring on a lab bench. While shimming was performed at the start of the experiment on the reactant itself, no extra shimming was required during the ten day experiment. Even gas bubbles in the measurement volume did not disrupt subsequent measurements.

Another application note describes the study the hydrolysis of acetic anhydride by water. Rate constants can easily and reliably be obtained by plotting the peak height or integral of a characteristic peak as a function of reaction time. The activation energy of the process can be determined by carrying out the reaction at different temperatures.


Digital Edition

International Labmate Buyers' Guide 2024/25

June 2024

Buyers' Guide featuring: Product Listings & Manufacturers Directory Chromatography Articles - Enhancing HPLC Field Service with fast-response, non-invasive flowmeters - Digital transformatio...

View all digital editions

Events

EuCheMS Chemistry Congress

Jul 07 2024 Dublin, Ireland

HPLC 2024

Jul 20 2024 Denver, CO, USA

ICMGP 2024

Jul 21 2024 Cape Town, South Africa

ADLM 2024

Jul 28 2024 San Diego, CA USA

InaLab 2024

Jul 30 2024 Jakarta, Indonesia

View all events