• Identifying Cannabinoids in Baked Goods with Minimal Sample Preparation

Microscopy & Microtechniques

Identifying Cannabinoids in Baked Goods with Minimal Sample Preparation

Thermo Fisher Scientific, Inc announced a new method for identifying marijuana cannabinoids in baked goods that is faster, easier-to-use and requires less sample preparation. Using ultra high performance liquid chromatography with mass spectrometry detection (UHPLC/MS), the application tests baked goods samples obtained from a local state police forensic laboratory and is detailed in the application note ‘Identification of Cannabinoids in Baked Goods by UHPLC/MS’.

The evidence is first screened for marijuana using simple chemical tests, such as the Duqenois-Levine test and then gas chromatography-mass spectrometry (GC/MS) is used to positively identify cannabinoids. This conventional technique works well for leaf marijuana, hashish and residue collected from smoking paraphernalia. UHPLC/MS however is an alternate method for identifying marijuana cannabinoids in complex food matrices such as baked goods.

Incorporating the Thermo Scientific Accela UHPLC system, the Thermo Scientific MSQ Plus Mass Detector, a single quadrupole mass spectrometer and Thermo Scientific Xcalibur software, the system detected marijuana cannabinoids, Δ9-tetrahydrocannabinol (THC), cannabinol and cannabidiol in the baked goods, a complex food matrix. The team delivered results with simpler sample preparation, no derivatisation and less instrument clean-up time.

The team extracted and separated cannabinoids on a Thermo Scientific Hypersil GOLD PFP column, and it showed that the cannabinoid standards eluted with good resolution at 4.1 minutes (cannabidiol), 5.1 minutes (THC) and 5.4 minutes (cannabinol). The extracts from a brownie and a cookie eluted at 5.1 minutes, testing positive for THC, demonstrating how little sample preparation is required for this method. It is simpler, faster and requires less sample material than traditional GC/MS techniques. Preparation time of ten minutes and a total run time of eight minutes shows the efficiency of UHPLC/MS detection.

The Accela™ is a high-speed chromatographic system that provides fast and efficient chromatographic separations over a range of flow rates and pressures. It features optimised system delay volumes for fast separations and flexible sample format. The innovative quaternary pump is capable of conventional and ultra-high pressures while the Thermo Scientific LightPipe technology provides maximum sensitivity and resolution.


Digital Edition

Lab Asia 31.6 Dec 2024

December 2024

Chromatography Articles - Sustainable chromatography: Embracing software for greener methods Mass Spectrometry & Spectroscopy Articles - Solving industry challenges for phosphorus containi...

View all digital editions

Events

Smart Factory Expo 2025

Jan 22 2025 Tokyo, Japan

Instrumentation Live

Jan 22 2025 Birmingham, UK

SLAS 2025

Jan 25 2025 San Diego, CA, USA

Arab Health

Jan 27 2025 Dubai, UAE

Nano Tech 2025

Jan 29 2025 Tokyo, Japan

View all events