• Temperature Controlled Stage used to study Metal-organic Frameworks using Second Harmonic Generation Microscopy

Microscopy & Microtechniques

Temperature Controlled Stage used to study Metal-organic Frameworks using Second Harmonic Generation Microscopy

Linkam Scientific Instruments report on the use of their THMS600 temperature controlled stage in the study of metal-organic frameworks using Second Harmonic Generation Microscopy at the University of Leuven.

With the advancement of technology and the demand for more in-depth information, newer microscopy techniques such as Second Harmonic Generation (SHG) Microscopy are being used by scientists worldwide to further their research.

Dr Karen Markey from the University of Leuven, Belgium, is one such researcher who is reaping the benefits of these advancements by using SHG Microscopy to investigate the structure of materials in a manner that cannot be achieved through other, more conventional microscopy techniques.

Dr Markey and her colleagues in the university’s molecular electronics and photonics department have been using and fine tuning an SHG technique developed by Assistant Professor Monique van der Veen from the Technical University of Delft that can allow them to study the structure of metal-organic frameworks (MOFs). As part of this set-up, they have generally been using a wide field microscope and, more recently, a laser scanning microscope with an intense frequency of 800 nm. The team take several images of the same sample, but use different polarisations of the laser light. Plotting the variation of SHG intensity as a function of the polarisation gives an insight into the crystal structure of the samples.

With such small variations in optical density being of such importance, the control of the environmental conditions in which the sample is being held becomes even more vital. This was possible using a Linkam THMS600 stage.

Dr Markey was particularly impressed by the variety of parameters that can be controlled by the stages, she said: ”You can easily set the desired temperature programs and also measure under N2 flow, which is important for the materials we work with. It is an ‘all in one’ solution.”

To see the full paper on this application please visit: www.linkam.co.uk/application-notes


Digital Edition

Lab Asia 31.6 Dec 2024

December 2024

Chromatography Articles - Sustainable chromatography: Embracing software for greener methods Mass Spectrometry & Spectroscopy Articles - Solving industry challenges for phosphorus containi...

View all digital editions

Events

Smart Factory Expo 2025

Jan 22 2025 Tokyo, Japan

Instrumentation Live

Jan 22 2025 Birmingham, UK

SLAS 2025

Jan 25 2025 San Diego, CA, USA

Arab Health

Jan 27 2025 Dubai, UAE

Nano Tech 2025

Jan 29 2025 Tokyo, Japan

View all events