• Temperature Controlled Stage used to study Metal-organic Frameworks using Second Harmonic Generation Microscopy

Microscopy & Microtechniques

Temperature Controlled Stage used to study Metal-organic Frameworks using Second Harmonic Generation Microscopy

Jun 10 2014

Linkam Scientific Instruments report on the use of their THMS600 temperature controlled stage in the study of metal-organic frameworks using Second Harmonic Generation Microscopy at the University of Leuven.

With the advancement of technology and the demand for more in-depth information, newer microscopy techniques such as Second Harmonic Generation (SHG) Microscopy are being used by scientists worldwide to further their research.

Dr Karen Markey from the University of Leuven, Belgium, is one such researcher who is reaping the benefits of these advancements by using SHG Microscopy to investigate the structure of materials in a manner that cannot be achieved through other, more conventional microscopy techniques.

Dr Markey and her colleagues in the university’s molecular electronics and photonics department have been using and fine tuning an SHG technique developed by Assistant Professor Monique van der Veen from the Technical University of Delft that can allow them to study the structure of metal-organic frameworks (MOFs). As part of this set-up, they have generally been using a wide field microscope and, more recently, a laser scanning microscope with an intense frequency of 800 nm. The team take several images of the same sample, but use different polarisations of the laser light. Plotting the variation of SHG intensity as a function of the polarisation gives an insight into the crystal structure of the samples.

With such small variations in optical density being of such importance, the control of the environmental conditions in which the sample is being held becomes even more vital. This was possible using a Linkam THMS600 stage.

Dr Markey was particularly impressed by the variety of parameters that can be controlled by the stages, she said: ”You can easily set the desired temperature programs and also measure under N2 flow, which is important for the materials we work with. It is an ‘all in one’ solution.”

To see the full paper on this application please visit: www.linkam.co.uk/application-notes


Digital Edition

International Labmate Buyers' Guide 2024/25

June 2024

Buyers' Guide featuring: Product Listings & Manufacturers Directory Chromatography Articles - Enhancing HPLC Field Service with fast-response, non-invasive flowmeters - Digital transformatio...

View all digital editions

Events

EuCheMS Chemistry Congress

Jul 07 2024 Dublin, Ireland

HPLC 2024

Jul 20 2024 Denver, CO, USA

ICMGP 2024

Jul 21 2024 Cape Town, South Africa

ADLM 2024

Jul 28 2024 San Diego, CA USA

InaLab 2024

Jul 30 2024 Jakarta, Indonesia

View all events