• The AquaLog The world’s first simultaneous fluorescence and absorbance Spectrophotometer for CDOM measurements

Mass Spectrometry & Spectroscopy

The AquaLog The world’s first simultaneous fluorescence and absorbance Spectrophotometer for CDOM measurements

The Aqualog is a fluorescence instrument for rapidly measuring and identifying CDOM in water. The measurement is based on fluorescence excitation-emission matrices (EEMS) corrected for all instrumental factors. These corrections require an absorbance measurement to also be performed on the water sample.

Key features

•    The only instrument to measure both fluorescence and absorbance spectra in a single instrument for water quality analysis
•    Up to 100 fold faster data acquisition rates than any other benchtop fluorometer
•    Table-top instrument based on a CCD detector for fast simultaneous readout of the entire emission spectrum
•    Software routines automatically correct data for inner filter effects, Rayleigh line scattering, water Raman scattering, normalize the intensity scale, and export data for analysis in industry standard 3rd party packages.

Its main benefits are:

-    Table-top instrument based on a TE cooled CCD detector for fast simultaneous readout of the entire emission spectrum, means less analysis time or more samples
-    Analysis of samples with orders of magnitude variation in concentration without the need for tedious dilutions
-    Eliminating sample aging, bleaching and dilution issues as experimental variables. AqualogTM measures fully corrected EEMs in seconds. Rapid acquisition reduces bleaching compared to ‘scanning’ instruments that require up to 100 times longer data collection, exposing the sample to damaging UV wavelengths the whole time.
-    The instrument is fully automated.

-    Software: The Aqualog software automatically:
    o    masks the Rayleigh scatter lines
    o    normalizes to traceable intensity standards (Quinine Sulfate or Raman Scattering)
    o    offers 2-dimensional profiling of the ‘integrated’ excitation and emission spectra from EEMs
    o    corrects and batch exports the data for multivariate analysis using the industry standard Parallel Factor Analysis (PARAFAC) method, reducing data analysis time by a factor of ten
-    Corrected UV-VIS absorbance detection path for stability and accuracy
-    Double grating excitation monochromator for superior stray light rejection
-    Matching bandpass for absorbance and fluorescence spectra
-    The optics: We only use aberration-corrected mirrors (no lenses) to increase the wavelength range, for you cannot get good anti-reflection coatings from 200 nm up through 850 nm or above. Lenses also suffer from chromatic aberrations, meaning different wavelengths focus at different depths in the samples, and consequently you lose sensitivity. 
-    Gratings: HORIBA, previously known as Jobin Yvon, has been designing and making ruled and holographic gratings for over 50 years. We use plane-ruled gratings in our instruments as opposed to cheaper holographic ones, because ruled gratings are much less dependent on polarization effects.
-    The excitation source is a 150 W ozone-free xenon lamp. It is mounted vertically to prevent sagging and keep the illumination of the sample optimal.
-    A photodiode reference detector monitors the intensity as a function of time and wavelength to correct for any change in output due age or wavelength, and ensure more repetitive measurements. This reference detector enables to correct both absorbance and fluorescence detector signals.

To contact us email at info-sci.fr@horiba.com or visit us at www.horiba.com


Digital Edition

Lab Asia 31.6 Dec 2024

December 2024

Chromatography Articles - Sustainable chromatography: Embracing software for greener methods Mass Spectrometry & Spectroscopy Articles - Solving industry challenges for phosphorus containi...

View all digital editions

Events

Smart Factory Expo 2025

Jan 22 2025 Tokyo, Japan

Instrumentation Live

Jan 22 2025 Birmingham, UK

SLAS 2025

Jan 25 2025 San Diego, CA, USA

Arab Health

Jan 27 2025 Dubai, UAE

Nano Tech 2025

Jan 29 2025 Tokyo, Japan

View all events