• Cocaine vs caffeine with the Specac Golden Gate

Laboratory Products

Cocaine vs caffeine with the Specac Golden Gate

Aug 30 2016

The Specac Golden Gate ATR accessory is available with a range of sampling options for advanced ATR material analysis, including ambient temperature (standard), heated, cooled, reaction cell, or super critical fluids.

The Golden Gate ATR makes us particularly proud because:

  • you can analyse samples without grinding them down
  • you can avoid the cross contamination of samples
  • results are reliable and easy to reproduce

Let’s look at how the Specac Golden Gate can be used by forensic scientists for the Fourier Transform Infrared (FTIR) spectroscopy analysis of drugs (or ‘substances’) both legal and otherwise.

Easy sample preparation

The analysis of powders and tablets often requires the user to grind up samples with Potassium Bromide (KBr) and then press them into a pellet or disc, for IR transmission testing.

But our Golden Gate ATR accessory saves the time of making KBr pellets.

A neat sample of powder or simply a solid sample can be placed onto the diamond ATR crystal and clamped into place by a manually-operated sapphire clamping anvil. The clamp can be removed for cleaning, so you can keep your accessory looking brand new.

Using this process helps to guarantee the quality of the spectra. What’s more, the original sample can be recovered afterwards for presentation as evidence or further analysis.

Just keep in mind that the relative peak intensity of the absorption bands will be different to those of pellet samples, due to the internal reflection mechanism of an ATR accessory.

Search your sample spectra against a digital database of ATR spectra to provide positive identification.

An example

So the spectrum is collected. For our results, this was done with some caffeine and some illegal drugs.

ZnSe lenses were used in the Golden Gate ATR (KR-5 lenses are available to increase spectral range) along with a single-reflection diamond ATR element.

After taking a background spectrum, FT-IR spectra of 36 scans at 4cm-1 resolution were co-added and averaged to obtain the single-beam background and sample spectra.

The total sampling time was approximately 2-5 minutes per sample, including sample clean-up and background collection.

Methamphetamine HCl, Amphetamine HCl, Caffeine, Cocaine HCl and Crack Cocaine were all tested.

The results

Check out the spectral data for Cocaine HCl and for Caffeine below.

The reading of Cocaine HCl compares a Golden Gate ATR reading to a transmission reading of a KBr pellet of Cocaine HCl.

The other reading simply shows the Golden Gain ATR’s spectral data of Caffeine.

Or you can get in touch with Specac with any questions on the product or its pricing.

Please view our video

Acknowledgements

Cynthia Koulis, Illinois State Police.

Richard A. Larson, Spectral Consulting


Digital Edition

International Labmate 49.6 - Sept 2024

September 2024

Chromatography Articles - HPLC gradient validation using non-invasive flowmeters Mass Spectrometry & Spectroscopy Articles - From R&D to QC, making NMR accessible for everyone: Putting NMR...

View all digital editions

Events

AQE 2024

Oct 09 2024 Birmingham, UK

WWEM

Oct 09 2024 NEC, Birmingham, UK

SPICA 2024

Oct 15 2024 Milan, Italy

Lab Bangladesh

Oct 17 2024 Dhaka, Bangladesh

SETAC North America

Oct 20 2024 Fort Worth, TX, USA

View all events