TOC analyser improves lab efficiency
Aug 04 2009
Leading instrumentation company HACH LANGE is helping a number of key customers save valuable time and costs with its new IL550 TOC-TN analyser.
Although closely related to both BOD and COD analysis, TOC is important in its own right because it is the sole analytical method able to quantify only those species that contain carbon. For this reason TOC is a parameter that is required by regulations in many industries, for example, as a waste acceptance criterion of hazardous waste TOC analysis is now compulsory. It also provides a number of key benefits over BOD and COD including a significantly improved analysis speed and higher accuracy.
The IL550 can also be used for the determination of dissolved organic carbon (DOC) as well as total organic carbon (TOC) in sewage, river, landfill leachates, effluents and groundwater samples. Subsequently, it has proved to be an important addition for HACH LANGE customers including the Environment Agency’s National Laboratory Services (NLS), South West Water and laboratory testing services company Chemtest.
At the NLS, much of the analytical work is for regulatory purposes, so it is vitally important that fast, accurate, reliable results are produced. Richard Yates, Inorganic Analysis Team Leader at the NLS, said: “The high calibration range of the IL550 reduces the number of over-range repeat analyses we have to perform, thereby saving valuable lab time and improving the sampling process. In addition, the instrument is very easy to use and meets our required limit of detection.”
Tracy Churchill, Senior Assistant Scientist for South West Water, also praised the benefits of the IL500. She explained: “The IL 550 software is very user-friendly, making it easy to train analysts. Additionally, and most importantly, because the analyser has a ‘stand-by’ mode we are able to leave the instrument on at a reduced temperature, which prolongs the life of the catalyst. As a result of these features we have significantly reduced downtime and maintenance costs, because previously we had to replace the catalyst on a fairly regular basis. We are delighted with the TOC-TN analyser and the results it is producing.”
The IL550 has also helped Chemtest save significant time and costs over the past year. Laboratory manager Darrell Hall said: “We have found the IL550 more reliable than the previous methods we used for TOC analysis on water and leachates samples and in general it has made the lab analysis process much more efficient.”
A key feature of the IL550 is particle tolerance in liquids. The autosampler needle has a large internal diameter and the sample is injected directly via the pneumatic port into the furnace – this eliminates blockages, cross-contamination or leaks because there is no septum or valve.
With the IL550, digestion takes place at up to 950 Deg C and the solids module is able to increase the temperature to an unrivalled 1300 Deg C. The UV version is equipped with a high-energy UV lamp, which offers the advantage of direct contact with the sample.
For a brochure or a quote, please contact sarah.blayds@hach-lange.co.uk