• Rotator Keeps Statutory Fertiliser Analysis Work Turning Over

Laboratory Products

Rotator Keeps Statutory Fertiliser Analysis Work Turning Over

Aug 26 2010

Kent Scientific Services, a Public Analyst Laboratory, selected a Stuart STR4 rotator to meet the requirements of its fertiliser enforcement analysis work. The prescribed analysis methods for checking the nitrogen and
phosphorus content in fertiliser samples require flasks to be mixed end-over-end at 35–40rpm, faster than many other rotators can achieve.

Nitrogen (N), Phosphorus (P) and Potassium (K) are the three primary nutrients needed in large quantities by plants. Manufactured fertilisers, used to supply crops with nutrients the soil lacks, have to be labelled with three figures indicating their NPK content. The Fertilisers (Sampling and Analysis) Regulations 1996 require the figures to be checked by standardised analysis techniques. Kent Scientific Services, one of 18 Public Analyst Laboratories in England, provides scientific and calibration services for local authority enforcement agencies, including analysis of fertiliser samples collected by local Trading Standards officers from manufacturers’ premises or at the point of sale.

David Heath, Quality Manager/Toxicology Manager at Kent Scientific Services, commented: “The prescribed analysis methods for soluble N and P require fertiliser samples to be mixed with 400ml of water in a volumetric flask and mixed by end-over-end rotation at 35–40rpm. The speed we needed was well within the range offered by the STR4. The Bibby Scientific engineering department were very helpful to us, adjusting the bracket on the rotator so that it would work with the large 500ml flasks we need to use.” The Stuart STR4 drive unit is highly versatile, accepting a choice of five drums designed to take test-tube holders, plates, racks of microcentrifuge tubes, conical flasks, reagent bottles, or jars and paint tins up to 200mm in length and 120mm diameter. The rotation speed is variable from 6 to 60rpm for a range of mixing applications, and the unit can be run in continuous operation mode or with the analogue timer set for 10 to 60 minutes.


Digital Edition

Lab Asia 31.4 August 2024

August 2024

Chromatography Articles - HPLC gradient validation using non-invasive flowmeters Mass Spectrometry & Spectroscopy Articles - MS detection of Alzheimer’s blood-based biomarkers   Labo...

View all digital editions

Events

Thailand Lab 2024

Sep 11 2024 Bangkok, Thailand

Bio Asia Pacific 2024

Sep 11 2024 Bangkok, Thailand

Medical Fair Asia 2024

Sep 11 2024 Singapore

ILMAC

Sep 18 2024 Lausanne, Switzerland

ICIF China 2024

Sep 19 2024 Shanghai, China

View all events