• Simultaneous Determination of Halogens and Sulphur in Complex Matrices by Combustion Ion Chromatography

Chromatography

Simultaneous Determination of Halogens and Sulphur in Complex Matrices by Combustion Ion Chromatography

Apr 15 2014

Combustion ion chromatography (CIC) enables straightforward, simultaneous determination of halogens and sulphur in complex solid and liquid matrices. CIC is ideal for routine analysis, as it integrates sample digestion by pyrolysis and subsequent analysis by ion chromatography in a single, fully automated system. There is no need for complicated method development, and sample throughput is higher than with competing methods. Whereas competing methods can only provide results for the total amount of halogens in the sample, CIC provides discrete results for each of the different halogens.

CIC is recommended for the determination of halogens and sulphur in fuels, lubricants, additives, polymers, flame retardants, textiles, special chemicals, catalysts, and all kinds of waste.

Recent applications developed by Metrohm are: AN-CIC-001 Halogens in high-viscosity oils by means of Combustion IC; AN-CIC-002 Halogens and sulphur in residual solvents by means of Combustion IC; AN-CIC-003 Chlorine, bromine and sulphur in low-density polyethylene (ERM®-EC680k) by means of Combustion IC; AN-CIC-004 Entire and leachable concentration of halogens and sulphur in latex gloves by means of Combustion Ion Chromatography and a leaching test; AN-CIC-005 Iodine in a pharmaceutical product by means of Combustion Ion Chromatography with Inline Matrix Elimination; AN-CIC-006 Recovery rates for chloride, bromide and sulphate in certified reference materials by means of Combustion Ion Chromatography; AN-CIC-007 Analysis of a mixed liquid standard by means of Combustion IC; AN-CIC-008 Fluorine in polyisobutene by means of Combustion IC; AN-CIC-009 Chloride and sulphur in cyclohexane by means of Combustion IC; AN-CIC-010 Halogens in a polymer sample by means of Combustion IC pursuant to RoHS; AN-CIC-011 Analysis of an ion exchanger by means of Metrohm Combustion IC; AN-CIC-012 Halogens and sulphur in clay using Combustion IC; AN-CIC-013 Analysis of certified liquefied gas using Combustion IC; AN-CIC-014 Chloride traces in the wax fraction of raw oil distillation using Combustion IC.


Digital Edition

International Labmate Buyers' Guide 2024/25

June 2024

Buyers' Guide featuring: Product Listings & Manufacturers Directory Chromatography Articles - Enhancing HPLC Field Service with fast-response, non-invasive flowmeters - Digital transformatio...

View all digital editions

Events

EuCheMS Chemistry Congress

Jul 07 2024 Dublin, Ireland

HPLC 2024

Jul 20 2024 Denver, CO, USA

ICMGP 2024

Jul 21 2024 Cape Town, South Africa

ADLM 2024

Jul 28 2024 San Diego, CA USA

InaLab 2024

Jul 30 2024 Jakarta, Indonesia

View all events